Facade Inspections & Testing
Maximize the performance of your facades. Our building envelope experts look at every angle to guarantee your facades meet thermal, structural, and moisture protection requirements.

Specify Right Facade Material

Ensure Building Compliance

Final Inspection & Diagnosis

Root Cause Leak Detection
Advanced Facade Inspections For Every Stage In The Building Lifecycle


Construction Phase
Comprehensive facade inspections during the build ensure efficient and quality construction.


Maintenance Phase
Routine facade inspections from our specialists help keep your building safe and operational, reducing the need for costly repairs.


Emergency Inspections
Our inspectors partner with you to identify and diagnose critical leak points in your facade, so repairs can be made.
ASTM Standards, Expertly Tested
Below are ASTM standards covered in our facade inspections & testing services:
ASTM E1105
Standard test method for field determination of water penetration of installed exterior windows, skylights, doors and curtain walls by uniform or cyclic static air pressure difference
AAMA 501.2
Quality assurance and diagnostic water leakage field check of installed storefronts, curtain walls and sloped glazing systems
ASTM E1060
Standard practice for thermographic inspection of insulation installations in envelope cavities of frame buildings
ASTM E1186
Standard practices for air leakage site detection in building envelopes and air barrier systems
Building Envelope Solutions Made Simple
Complete Inspection & Testing Packages for Better Performance
Ensure quality and efficiency with our bundled service packages.
Facade Quality Assurance Package
Thorough independent reviews of your facade to ensure quality of construction and maintenance and to detect any leak entry points.
INCLUDES:Â
- Visual facade inspections
- Sealant pull tests
- Detection of any leak entry points facade contractors may have missed
OUTCOMES:Â
- Fulfill warranty compliance requirements
- Verify facade system is installed correctly
- Verify installed system is maintained in water-tight and warrantable condition
ASTM STANDARDS:Â
ASTM C1153
Commercial Facade Inspections & Testing FAQs
How long does sealant last?
Different types of sealant last for different amounts of time. Urethane sealants are deteriorated by sunlight and break down due to extended exposure. Silicone sealant reacts slower to UV exposure and therefore lasts longer.
What is the most common source of leakage in masonry wall systems?
Thru-wall flashing is the most common leak source. The flashing is an integral part of the system that is not visible once the wall is constructed. If not properly installed, water bypasses the flashing and leaks into the building.
What testing provides verification that an AVB is properly installed?
ASTM E1186 is commonly followed to confirm installation methodologies. PosiTesting (bubble testing) is commonly used to test for air leakage through the AVB system.

Inquire About Commercial Facade Inspections & Testing
"*" indicates required fields
"*" indicates required fields